  • In a computed radiography plate reader, which component converts the captured analog signal into a digital signal?
  • Which component is the smallest sensing unit that converts radiation interactions into an electrical signal in digital radiography?
  • In a common computed radiography plate reader, which combination of components is used to convert the captured signal to digital form?
  • Which layer of a computed radiography (CR) imaging plate is responsible for creating the latent image?
  • Photons that add information but do not represent anatomy are considered?
  • For the highest spatial resolution, which combination should be used?
  • What type of noise cannot be reduced
  • Cesium iodide is the preferred material for the scintillation layer because it can be formed into:
  • What is the main disadvantage of accessing the Medical Image Management and Processing System (MIMPS) server through the internet on a basic desktop computer and monitor?
  • Which component of an indirect capture flat-panel detector converts incident x-ray photons into visible light photons?
  • Exposure latitude is best defined as which of the following?
  • Which term best describes a blotchy appearance caused by an insufficient number of photons reaching the image receptor?
  • What are the detector elements (DELs) in a digital radiography detector primarily responsible for?
  • Which factor is most closely associated with quantum mottle?
  • Which of the following would lead to an increase in patient dose?
  • What is the term for the logical path data follows from source to destination, determined by routing protocols?
  • What does MIMPS stand for?
  • Which device acts as the switch within a flat-panel detector to release the collected charge?
  • Which radiographic matrix will produce the image with the smallest pixel size?
  • The Food and Drug Administration (FDA) regulates software functions that allow for a practitioner to manage patient care through the processing, manipulation, enhancement, or review of:
  • In a flat-panel detector stack used for indirect capture, which component is typically responsible for collecting the electrical signal produced by the light from the scintillator?
  • What is the primary purpose of the PSP layer in computed radiography?
  • Which process corrects slight under-exposure or over-exposure errors made by the technologist?
  • Which of the following makes up the digital matrix of the image file?
  • What does PACS stand for?
  • What units are used to express spatial frequency?
  • Which device is used to capture and generate medical imaging data in a MIMPS network?
  • During CR readout, which action does the laser perform on the PSP layer?
  • The digital image receptor is comprised of small elements called what?
  • Which Modulation Transfer Function score is highest?
  • In a CCD-based digital radiography system, which coupling method connects the scintillation layer to the CCD sensor chips?
  • The image on receptor is created by the arrangement of detector elements into rows and columns. What is this arrangement called?
  • In an indirect capture detector, which layer converts x-ray energy into visible light?
  • Federal regulations require medical images stored in how many locations?
  • Which spatial frequency would produce the greatest spatial resolution?
  • In computed radiography, the latent image is stored in which layer of the cassette?
  • Which statement best describes the radiographic signal?
  • Which condition increases the signal-to-noise ratio in radiography?
  • What is the primary function of the analog-to-digital converter in a CR imaging system?
  • A radiography setting shows upright Bucky images with noise; what is most likely source?
  • After reading a CR plate, what happens to the latent image?
  • Which charge does the storage capacitor of a detector element (DEL) store?
  • Processing a tibia-fibula radiograph as an abdomen may result in which of the following?
  • Which is the smallest exposure difference that can be detected and displayed by the imaging system?
  • Within a digital radiography image matrix, 1024 x 1024 refers to the:
  • The Modulation Transfer Function (MTF) evaluates the:
  • Which part of the detector element detects radiation?
  • What is the percentage of the detector element (DEL) devoted to the detection layer called?
  • Which layer of the CR imaging plate prevents unwanted light from reaching the latent image?
  • What term describes the maximum rate at which data can be transmitted over a network path under ideal conditions?
  • Which change would most likely decrease spatial resolution?
  • Which approach to increasing the signal may lead to an increase in scatter reaching the image receptor (IR)?
  • Quantization takes place in digital radiography in which component?
  • Which process is used to correct slight exposure errors?
  • Which of the following technologist errors is most likely to result in incorrect histogram rescaling and look-up table adjustment?
  • Which component provides display capability for studies at reading stations?
  • Calculate the pixel size given these variables: Matrix size = 512 x 512 Field-of-view (FOV) = 12cm Milliamperes (mA) = 5 Kilovoltage peak (kVp) = 78
  • What part of the Medical Image Management and Processing System (MIMPS) houses all of the historic digital image data along with the current digital data being generated by the modalities?
  • What is the relationship between the fill factor and spatial resolution?
  • Which device serves as an interface to connect networks that use different protocols and can act as a gateway between them?
  • Which term describes the spatial detail of the digital image, often influenced by the physical size of detector elements?
  • Which material used in flat-panel detectors directly converts x-ray photons into an electrical signal?
  • Which factor influences the grayscale of a digital radiograph?
  • Which Modulation Transfer Function (MTF) score indicates that an image perfectly represents the object in both spatial resolution and contrast?
  • In an indirect capture flat-panel detector system, which layer is responsible for converting x-ray energy into light?
  • In a flat-panel detector, which component is used to read out the signal from the detector array (acts as the switching matrix)?
  • Using a radiographic grid affects image quality by which primary mechanism?
  • What does the acronym DQE stand for?
  • In computed radiography, which technology may be used in place of the photomultiplier tube (PMT) in the image reader system?
  • Out of the given lines pers millimeter (lp/mm) selections for spatial frequency, which would represent the highest Modulation Transfer Functions (MTF) score?
  • Which configuration yields the highest spatial resolution?
  • A histogram in digital radiography refers to the:
  • Which standard enables interchange of medical images and related data between radiology devices and information systems?
  • Which standard defines radiology image formatting?
  • Which statement best describes the relationship between histogram axes?
  • Which bit depth enables the greatest amount of anatomic information in a digital radiography image?
  • The thin, active layer within the computed radiography (CR) cassette stores which of the following?
  • In a healthcare network, which encryption method is commonly used to secure data transmitted over public networks?
  • In a CCD-based system, the scintillation layer is connected to the CCD sensor chips by what method?
  • Quantization is a digital radiography process through which receptor readings are:
  • What term describes a 3D volume element in imaging data?
  • Which action helps reduce system noise in digital radiography?
  • When a radiograph has high DQE, what combination of signal and noise is typically observed?
  • Using the provided relationship, calculate spatial frequency when the pixel size is 0.04 mm.
  • Which unit is used to express spatial frequency in radiography?
  • What is another name for the conductive layer of a computed radiography plate?
  • Which term best describes a collection of connected computers that share resources within a limited area?
  • Which adjustment is preferred when radiographic grids are used to reduce scatter?
  • The artifact from exposure beyond the imaging latitude is called what?
  • What makes up the capture area of a detector element (DEL)?
  • Which device is primarily used to connect multiple devices within a LAN and forwards frames based on MAC addresses?
  • Which of the following components is NOT utilized in an indirect capture flat-panel digital image detector system?
  • Consider an exposure that results in a receptor exposure of 0.001 microgray. The resulting image is expected to display which artifact?
  • The acronym PSP in CR stands for:
  • Detective Quantum Efficiency (DQE) is a:
  • Which factor influences Modulation Transfer Function (MTF)?
  • What negative impact occurs when a MIMPS network runs through a standard web-based network?
  • The detector's exposure range from 0.1 microgray to 1,000 microgray defines which characteristic?
  • Which statement best describes the role of MIMPS in a healthcare IT environment?
  • What is the primary advantage of an Internet-based Medical Image Management and Processing System (MIMPS) network?
  • Imaging and archiving systems in radiology communicate using a digital format called:
  • Which statement correctly describes Detective Quantum Efficiency?
  • Amorphous selenium is a material used in which imaging system?
  • Which device transfers the latent image within the imaging plate to a viewable digital radiograph?
  • Which term describes the percentage of the detector element area devoted to the detection layer?
  • Which term describes the fraction of incident photons that are absorbed by the detector?
  • Which digital format is used to communicate imaging data in radiology?
  • What is the practice called when a network is divided into smaller segments to reduce collisions and improve performance?
  • The acronym MTF stands for which of the following?
  • Which of the following factors influences Modulation Transfer Function (MTF)?
  • Which term describes a network that covers a large geographic area, often using public or leased telecom lines?
  • Which of the following is essential to transfer a latent image from the imaging plate to a digital radiograph?
  • How does high Detective Quantum Efficiency (DQE) affect the required exposure to achieve a given image quality?
  • Which option is NOT a core part of a MIMPS network’s typical components list?
  • The term latent image refers to what phenomenon in imaging plates?
  • Which statement about exposure indicators and histogram analysis is true?
  • How many radiologists can open an exam simultaneously in Medical Image Management and Processing System (MIMPS)?
  • Which statement best describes a typical advantage of digital radiography over computed radiography?
  • In a digital radiography setup, why is it poor practice to rely on image brightness alone to judge exposure when exposure indicators are missing?
  • Which statement best describes a radiography system with high Detective Quantum Efficiency (DQE)?
  • In imaging terminology, what is the smallest addressable element of the digital image produced by the detector array?
  • Which of the following will produce the highest spatial resolution?
  • Flat-panel detector systems typically use a thin-film transistor (TFT). This device functions to:
  • Calculate the spatial frequency if the pixel size is 0.03 mm.
  • What step in digital image processing identifies the useful exposure values ('values of interest') in raw image data?
  • What does the acronym MIMPS stand for?
  • Which device examines all data and limits the data scope by sender/receiver?
  • What unit is used to express spatial frequency in radiography?
  • Which component displays the digitized image for radiologic interpretation?
  • Which of the following is the ability to produce quality radiographs at a wide range of technical factors?
  • In digital radiography, the adjustment of brightness and contrast is achieved through which processing step?
  • The X-axis of the radiographic histogram represents the
  • Which phenomenon describes the delay variation in packet arrival times within a network?
  • In the radiographic histogram, what does the Y-axis represent?
  • What interaction is primarily responsible for x-ray absorption in the phosphor layer at diagnostic energies?
  • The capture area of a detector element is defined by which combination of components?
  • Patient records are shared between medical providers using which of the following?
  • When compared to computed radiography (CR), digital radiography (DR) is:
  • Which layer on a CR imaging plate primarily prevents unintended erasure of the latent image by ambient light?
  • The phosphor layer of the computed radiography (CR) imaging plate is composed of:
  • During CR readout, which action does the laser perform on the PSP layer?
  • In a flat-panel detector, which component stores the charge on a per-pixel basis prior to readout?
  • What does PSP stand for in computed radiography?
  • Which component is not utilized for computed radiography (CR) systems?
  • In a MIMPS network, which component is used for long-term storage of imaging data?
  • What is the primary disadvantage of viewing and interpreting diagnostic studies directly through the Medical Image Management and Processing System (MIMPS) server?
  • Bit depth is defined as the:
  • Which material is responsible for storing the latent within the CR imaging plate?
  • An radiographer acquires an optimal wrist image at 60 kVp and 2.5 mAs. If the same projection is acquired at 72 kVp and 5 mAs, which outcome is most likely?
  • Which of the following would decrease the Detective Quantum Efficiency (DQE)?
  • An x-ray photon is absorbed with the phosphor layer of a CR plate through what type of interaction?
  • In digital radiography, increasing bit depth primarily improves which aspect?
  • Which term describes the set of exposure values that the receptor can accurately capture?
  • Which change will increase the contrast resolution of a digital radiographic system?
  • What is a common device radiologists use to interpret images in a MIMPS network?
  • Increasing bit depth in digital radiography primarily affects which aspect?
  • Which layer of the CR imaging plate prevents unwanted light and background radiation from affecting the unprocessed latent image?
  • An x-ray exposure above the highest level of the exposure latitude may result in which image error?
  • Which component of MIMPS is responsible for storing historical and current digital image data?
  • Detective Quantum Efficiency (DQE) is an actual number represented in a percentage. Which percentage below would be considered the highest DQE?
  • What is the role of the photomultiplier tube in a CR system?
  • Which device is commonly used to connect multiple networks and can perform NAT to share a single public IP?
  • What term describes computers that are all connected and serve as infrastructure for handling informational transactions between multiple parties?
  • If a digital detector has a larger bit depth, what is the effect?
  • What happens when a computed radiography (CR) imaging plate is exposed to white light?
  • Photon is synonymous with which term?
  • If a chest radiograph is taken with a lower mAs than appropriate, which digital process is used to display the image as if the receptor was exposed correctly?
  • Which component provides immediate access to prior studies within a MIMPS network?
  • The conductor layer within the computed radiography (CR) imaging plate is responsible for which of the following?
  • How many grayscale levels can an 8-bit digital radiography system display?
  • Which component of a detector element stores the charge collected from radiation?
  • Which statement describes the use of Electronic Health Records (EHR) in sharing patient records?
  • Which device may be used in place of the photomultiplier tube (PMT) within a computed radiography (CR) image reader system?
  • A single detector element (DEL) comprises which set of components?
  • In the context of medical imaging networks, what term describes a system used to store, retrieve, and display images?
  • Which artifact is most associated with extremely low receptor exposure?
  • Which term is not a standard imaging element in radiography and is often used as a distractor in practice questions?
  • In an indirect capture flat-panel detector, which component converts visible light into electrons?
  • When should a computed radiography imaging plate be processed to prevent loss of the latent image?
  • Dynamic range in radiographic imaging is defined as the:
  • Which term describes a secure method for connecting remote sites over the internet?
  • If two radiographers produce exposures with different kVp and mAs but similar dose indicators and patient dose, this demonstrates which concept?
  • Which statement describes what happens when energy is trapped in a CR imaging plate?
  • Which coding system is used for diseases in health records?
  • Which process is used to display the digital image with the ideal brightness and contrast?
  • Which of the following increases the Detective Quantum Efficiency (DQE)?
  • Which component is not typically a part of computed radiography (CR) systems?
  • What is the relationship between spatial frequency and the Modulation Transfer Function (MTF)?